Product Details
Place of Origin: China Mainland
Brand Name: Tankii
Certification: ISO9001
Model Number: J
Payment & Shipping Terms
Minimum Order Quantity: Negotiation
Price: Negotiation
Packaging Details: Standard exoprt package in carton box or wooden box
Delivery Time: 5-7 days after getting the payment
Payment Terms: T/T, Paypal, Western Union, MoneyGram,
Supply Ability: 1000Ton per year
Standard: |
ANSI, IEC584 |
Application: |
Thermocouple,temperature Measurement |
Diameter: |
Customized |
Delivery Time: |
5~10 Days After Getting The Payment |
Conductor Type: |
Single /stranded |
Shape: |
Wire On Bobbin |
Standard: |
ANSI, IEC584 |
Application: |
Thermocouple,temperature Measurement |
Diameter: |
Customized |
Delivery Time: |
5~10 Days After Getting The Payment |
Conductor Type: |
Single /stranded |
Shape: |
Wire On Bobbin |
Thermocouple Alloys Type J White 0.2mm Thermocouple Wire for Thermocouple Extension Alloy Wires
Thermocouple wire allows temperatures to be measured electronically. A typical thermocouple construction consists of a pair of dissimilar metals that are electrically joined together at the sensing point and connected to a voltage measuring instrument at the other end. When one junction is hotter than the other, a thermal “electromotive” force (in millivolts) is produced that is roughly proportional to the difference in temperature between the hot and cold junctions.
Material | melting point | Resistivity |
Pure Rhodium(99.99%) | 1963 | 12.44 |
Pure Platinum(99.99%) | 1772 | 21.45 |
Pt-Rh6% | 1830 | 20.7 |
Pt-Rh10% | 1860 | 19.8 |
Pt-Rh20% | 1905 | 18.8 |
Pt-Rh30% | 1927 | 17.6 |
Specification: 0.015~41.2(mm) in round wire, strip: 60.1~0.5(mm) | ||
Application: Gas sensor. All kinds of sensors, medical components. Electric level and heating probe, etc. |
Thermocouple type and index |
Measurement Range ℃ |
|
Type |
Index |
|
|
B | 600~1700 |
|
R | 0~1600 |
|
S | 0~1600 |
|
K | -200~1300 |
|
E | -200~900 |
|
J | -40~750 |
|
T | -200~350 |
|
N | -200~1300 |
The allowable grade and Tolerance are obtained at 0℃
Thermocouple |
Grade |
Temperature range |
Allowable Tolerance /℃ |
Type B | Ⅱ | 600~1700 | ±0.25% t |
Ⅲ | 600~800 | ±4 | |
800~1700 | ±0.5%t | ||
Type R(S) | Ⅰ | 0~1100 | ±1 |
1100~1600 | ±[1+(t-1100) ×0.3%] | ||
Ⅱ | 0~600 | ±1.5 | |
600~1600 | ±0.25% t | ||
Type K and Type N | Ⅰ | -40~1100 | ±1.5℃ or ±0.4%t |
Ⅱ | -40~1300 | ±2.5℃ or ±0.75%t | |
Ⅲ | -200~40 | ±2.5℃ or ±1.5%t | |
Type E | Ⅰ | -40~1100 | ±1.5℃ or ±0.4%t |
Ⅱ | -40~1300 | ±2.5℃ or ±0.75%t | |
Ⅲ | -200~40 | ±2.5℃ or ±1.5%t | |
Type J | Ⅰ | -40~750 | ±1.5℃ or ±0.4%t |
Ⅱ | -40~750 | ±2.5℃ or ±0.75%t | |
Type T | Ⅰ | -40~350 | ±0.5℃ or ±0.4%t |
Ⅱ | -40~350 | ±1.0℃ or ±0.75%t | |
Ⅲ | -200~40 | ±1.0℃ or ±1.5%t |
Product details: